Summary:
For Huawei transmission equipment OptiX OSN 1800 V100R003C01SPC200 (5.67.03.23) or an earlier version, services on the TNF2LQM or TNF2LDGF2 board that uses the service chip of version V110 will be unavailable after the board is initialized because of a bug. The problem can be resolved by upgrading the OptiX OSN 1800 to V100R003C01SPC300 (5.67.03.25) or a later version.
[Problem Description]
Trigger conditions:
The problem occurs when the following conditions are present:
The TNF2LQM or TNF2LDGF2 board uses the service chip of version V110.
The NE software version is V100R003C01SPC200 or earlier.
Symptom:
Services are unavailable after the board is powered on and configured with services.
Identification method:
Run the following command to query the service chip version on the board:
:woptp:$bid,1,83,1,ff,23,00,04,10,00,2 # "bid" indicates the slot ID of the TNF2LQM or TNF2LDGF2 board in the hexadecimal format.
The following information may be returned:
Optp cmd : ff23
00 04 10 00 02 87 51 00 11 # "00 11" indicates that the service chip version is 110.
If "00 11" is displayed in the returned information, the board is involved in this warning.
[Root Cause]
For Huawei OptiX OSN 1800 V100R003C01SPC200 and earlier versions, the TNF2LQM and TNF2LDGF2 boards that use the service chip of version V110 have a bug in board initialization.
[Impact and Risk]
Affected scope: in and out of China
Risk: The services are unavailable.
[Measures and Solutions]
Recovery measures:
Upgrade the OptiX OSN 1800 to V100R003C01SPC300 or later and perform a cold reset on the involved board.
Workarounds:
None
Preventive measures:
See "Recovery measures" as described above.
V100R003C01SPC300+V100R003C01SPH310 is a mainstream version of the OptiX OSN 1800 and addresses the known anomalies of V100R003C01SPC200 and earlier versions
V100R003C01SPC300+V100R003C01SPH310 (a mainstream version V100R003C01SPC300 with its hot patch V100R003C01SPH310) addresses the known anomalies of the OptiX OSN 1800 V100R003C01SPC200 and earlier versions. Upgrading the live network versions to the mainstream maintenance version V100R003C01SPC300+V100R003C01SPH310 is recommended
Upgrade the live network versions to V100R003C01SPC300+V100R003C01SPH310.
If the NMS needs to be upgraded, prepare for upgrading a license; refer to the template in the following attachment and submit a license rectification demand list.
[Problem Description]
V100R003C01SPC300+V100R003C01SPH310 is a mainstream version of the OptiX OSN 1800 and addresses the known anomalies of V100R003C01SPC200 and earlier versions. According to version policies, upgrading the live network versions to V100R003C01SPC300+V100R003C01SPH310 is recommended.
V100R003C01SPC300+V100R003C01SPH310 resolves the following issues:
For more Huawei transmission product please check Thunder-Link, Integration vantage resources, provide full series of Huawei Optical transmission products and solutions, including Huawei Metro Series, Huawei OSN Series MSTP, Huawei OSN Series DWDM, Huawei RTN Series Microwave, Huawei ATN/PTN Series equipment, modules and accessories. but also provide Huawei enterprise products,such as Router,Switch, WIFI,GPON,etc.